Structures Design
| For QPL Drawings, see Specifications Office - Qualified Products List (QPL) for Structural Materials |
Approved Post-Tensioning System Vendor Drawings by Category for Strand Tendons |
| Bonded Internal Monolithic Construction without Duct Couplers |
| Vendor | Post-Tensioning System | Document | Date | Size |
| VStructural LLC (VSL) | SA 6-4 | A 171, SA 6-4 Complete Component Assembly | 5/8/06 | 0.08MB |
|
A 161, SA 6-4 Assembly |
5/8/06 | 0.18MB | ||
| VStructural LLC (VSL) | ECI 6-19 | ECI 6-19 | 6/10/10 | 7.46MB |
| ECI 6-19 Alternate Grout Vent Details | 8/14/12 | 0.82MB | ||
| VStructural LLC (VSL) | NCS 6-27 | NCS 6-27 | 6/21/10 | 5.31MB |
| VStructural LLC (VSL) | NCS 6-31 | NCS 6-31 | 8/15/11 | 10.1MB |
| Bonded Internal Monolithic Construction with Duct Couplers |
| Vendor | Post-Tensioning System | Document | Date | Size |
DSI |
100 4-0.6 FMA 1"x3" Duct |
System Drawing - FA6804019 |
5/31/07 |
0.22MB |
| Pocket Former - 68042640 | 5/31/07 | 0.15MB | ||
| Grout Cap - 68042539 | 5/31/07 | 0.22MB | ||
| FMA Anchor - 68042531 | 5/31/07 | 0.19MB | ||
| Wedge Plate - 68042534 | 5/31/07 | 0.19MB | ||
| Corrugated Duct 1"x3" - S20A22600 | 5/31/07 | 0.15MB | ||
| Duct Coupler - S20A11600 | 5/31/07 | 0.05MB | ||
| DSI | 100 7-0.6 MA (Internal) | System Drawings | 2/30/13 | 3.49MB |
| DSI | 100 12-0.6 MA (Internal) | Part 1 | 2/08/08 | 1.94MB |
| w/ 76mm diameter duct | Part 2 | 2/08/08 | 1.93MB | |
| DSI | 100 12-0.6 MA (Internal) | Part 1 | 9/14/07 | 2.19MB |
| w/ 85mm diameter duct | Part 2 | 9/14/07 | 2.07MB | |
| DSI | 100 19-0.6 MA (Internal) | Part 1 | 9/14/07 | 2.22MB |
| Part 2 | 9/14/07 | 2.07MB | ||
| DSI | 100 27-0.6 MA (Internal) | Part 1 | 9/14/07 | 2.23MB |
| Part 2 | 9/14/07 | 2.07MB | ||
| Freyssinet | Universal Items Common to F and C Range Systems |
Universal Items | 7/22/13 | 0.76MB |
| Freyssinet | 4F15 | FINC-4F15 | 7/22/13 | 1.34MB |
| Freyssinet | 4C15 | FINC-4C15 | 7/22/13 | 1.26MB |
| Freyssinet | 7C15 | FINC-7C15 | 7/22/13 | 1.36MB |
| Freyssinet | 12C15 | FINC-12C15 | 7/22/13 | 1.41MB |
| Freyssinet | 13C15 | FINC-13C15 | 7/22/13 | 1.35MB |
| Freyssinet | 19C15 | FINC-19C15 | 7/22/13 | 1.36MB |
| Freyssinet | 27C15 | FINC-27C15 | 7/22/13 | 1.40MB |
| Freyssinet | 31C15 | FINC-31C15 | 7/22/13 | 1.55MB |
| VStructural LLC (VSL) | SA6-4 |
A 188 GTI 21x72 Duct and Coupler Complete Component Assembly |
5/8/06 | 0.09MB |
| A 186 GTI 21x72 Duct and Coupler Assembly | 5/8/06 | 0.19MB | ||
| VStructural LLC (VSL) | V-SLAB 6-4 | VSLAB 6-4 | 2/1/12 | 4.02MB |
| VStructural LLC (VSL) | ECI 6-7 with PT Plus Duct | A 180 Overall Assembly | 4/6/06 | 0.11MB |
| A 155 Anchorage Assembly | 4/5/06 | 0.23MB | ||
| A 184 Anchorage to Steel Pipe Assembly | 4/5/06 | 0.05MB | ||
| A 183 59mm Duct Coupler | 4/5/06 | 0.07MB | ||
| A 185 59mm Duct to Steel Pipe Connection | 4/5/06 | 0.06MB | ||
| ECI 6-7 Alternate Grout Vent Details | 8/14/12 | 0.81MB | ||
| VStructural LLC (VSL) | ECI 6-12 with PT Plus Duct | A 191 Overall Assembly | 4/26/05 | 0.11MB |
| A 154 Anchorage Assembly | 4/5/06 | 0.15MB | ||
| A 189 Anchorage to Steel Pipe Assembly | 4/5/06 | 0.05MB | ||
| A 190 76mm Duct Coupler | 4/5/06 | 0.07MB | ||
| A 192 76mm Duct to Steel Pipe Connection | 4/5/06 | 0.06MB | ||
| ECI 6-12 Alternate Grout Vent Details | 8/14/12 | 0.82MB | ||
| VStructural LLC (VSL) | ECI 6-19 | ECI 6-19 | 6/10/10 | 7.46MB |
| ECI 6-19 Alternate Grout Vent Details | 8/14/12 | 0.82MB | ||
| VStructural LLC (VSL) | ECI 6-19 with GTI Duct | A 178 Overall Assembly | 5/8/06 | 0.11MB |
| A 175 100mm GTI Duct Connection | 5/8/06 | 0.21MB | ||
| A 179 Tendon w/ Steel Pipe Assembly | 5/8/06 | 0.07MB | ||
| A 176 GTI Duct Connection | 5/8/06 | 0.08MB | ||
| A 177 GTI 100mm to Pipe Connection | 5/8/06 | 0.08MB | ||
| ECI 6-19 Alternate Grout Vent Details | 8/14/12 | 0.82MB | ||
| VStructural LLC (VSL) | ECI 6-19 with GTI 85mm Duct | A 225 Overall Assembly | 12/14/07 | 0.12MB |
| NOTE: This system approved | A 226 Anchorage Assembly | 12/14/07 | 0.22MB | |
| for use with a maximum of | A 228 GTI Duct to Duct Connection | 12/14/07 | 0.09MB | |
| 16-0.6" diameter strands. | A 179 Anchorage and Alternate Steel Pipe Connection | 05/08/06 | 0.07MB | |
| A 227 GTI 85mm Duct to Steel Pipe Connection | 12/14/07 | 0.09MB | ||
| ECI 6-19 Alternate Grout Vent Details | 8/14/12 | 0.82MB | ||
| VStructural LLC (VSL) | NCS 6-27 | NCS 6-27 | 6/21/10 | 5.31MB |
| VStructural LLC (VSL) | NCS 6-31 | NCS 6-31 | 8/15/11 | 10.1MB |
| Bonded Internal Segmental Construction with Segmental Duct Couplers |
| Vendor | Post-Tensioning System | Document | Date | Size |
| DSI | 100 12-0.6 MA (Internal) | Part 1 | 07/11/08 | 3.51MB |
| w/76mm GTI Duct and Segmental Couplers |
Part 2 | 07/11/08 | 2.26MB | |
| VStructural LLC (VSL) | ECI 6-12 with 76mm PT Plus | ECI 6-12 | 03/03/10 | 5.86MB |
| Duct and Segmental Couplers | ECI 6-12 Alternate Grout Vent Details | 8/14/12 | 0.82MB | |
| VStructural LLC (VSL) | ECI 6-19 with 100mm PT Plus | ECI 6-19 | 06/10/10 | 7.46MB |
| Duct and Segmental Couplers | ECI 6-19 Alternate Grout Vent Details | 8/14/12 | 0.82MB | |
| VStructural LLC (VSL) | NCS 6-27 with 130mm PT Plus Duct and Segmental Couplers | NCS 6-27 | 6/21/10 | 5.31MB |
| VStructural LLC (VSL) | NCS 6-31 with 130mm PT Plus Duct and Segmental Couplers | NCS 6-31 | 08/15/11 | 10.1MB |
| Unbonded External Segmental Construction with Bonded Anchors |
| Vendor | Post-Tensioning System | Document | Date | Size |
| DSI | 100 12-0.6 MA (External) | Part 1 | 12/18/07 | 2.08MB |
| Part 2 | 12/18/07 | 2.22MB | ||
| DSI | 100 19-0.6 MA (External) | Part 1 | 12/18/07 | 2.57MB |
| Part 2 | 12/18/07 | 2.22MB | ||
| DSI | 27-0.6 MA (External) | Part 1 | 12/18/07 | 2.04MB |
| Part 2 | 12/18/07 | 2.27MB | ||
| VStructural LLC (VSL) | ECI 6-19 | ECI 6-19 | 06/10/10 | 7.46MB |
| ECI 6-19 Alternate Grout Vent Details | 8/14/12 | 0.82MB | ||
| VStructural LLC (VSL) | NCS 6-27 | NCS 6-27 | 6/21/10 | 5.31MB |
| VStructural LLC (VSL) | NCS 6-31 | NCS 6-31 | 8/15/11 | 10.1MB |
| Unbonded External Construction with Unbonded Anchors (Rehabilitation or Add-on Tendons) |
| None Currently Approved |
Approved Post-Tensioning System Vendor Drawings by Category for Bar Tendons |
| Bonded Internal Monolithic Construction without Duct Couplers |
| Vendor | Post-Tensioning System | Document | Date | Size |
| DSI | 1" Threadbar PT Bar System 100 |
System Drawings | 9/22/08 | 3.14MB |
| DSI | 1-1/4" Threadbar PT Bar System 100 |
System Drawings | 9/22/08 | 3.60MB |
| DSI | 1-3/8" Threadbar PT Bar System 100 |
System Drawings | 9/22/08 | 3.21MB |
| Williams Form | R7P | R7P System Layout Standard Nut | 10/18/04 | 0.42MB |
| Engineering Corp | R7P System Layout Spherical Nut | 1/25/05 | 0.43MB | |
| R7P Master Item Component Parts | 10/18/04 | 0.53MB | ||
| R7P Typical Optional Parts | 10/18/04 | 0.34MB | ||
| R7P Vertical Assembly Details | 10/7/04 | 0.76MB | ||
| R7P Horizontal Assembly Details | 10/7/04 | 0.76MB | ||
| VStructural LLC (VSL) | 1-1/4" and 1-3/8" PT Bar System | System Drawings | 6/21/10 | 6.84MB |
| See Type C for use with Segmental Coupler | Optional Grout Cap
Conditional Approval: Click here for more information |
|||
| VStructural LLC (VSL) / Williams |
1-3/4" Bar System | System Drawings | 2/14/12 | 3.16MB |
| Bonded Internal Monolithic Construction with Duct Couplers |
| Vendor | Post-Tensioning System | Document | Date | Size |
| VStructural LLC (VSL) | 1-1/4" and 1-3/8" PT Bar System | System Drawings | 6/21/10 | 6.84MB |
| See Type C for use with Segmental Coupler | Optional Grout Cap
Conditional Approval: Click here for more information |
|||
| VStructural LLC (VSL) / Williams |
1-3/4" Bar System | System Drawings | 2/14/12 | 3.16MB |
| Bonded Internal Segmental Construction with Segmental Duct Couplers |
| Vendor | Post-Tensioning System | Document | Date | Size |
| VStructural LLC (VSL) | 1-1/4" and 1-3/8" PT Bar System | System Drawings | 6/21/10 | 6.84MB |
| Optional Grout Cap
Conditional Approval: Click here for more information |
| Unbonded External Segmental Construction with Bonded Anchors |
| Vendor | Post-Tensioning System | Document | Date | Size |
| VStructural LLC (VSL) | 1-1/4" and 1-3/8" PT Bar System | System Drawings | 6/21/10 | 6.84MB |
| Optional Grout Cap
Conditional Approval: Click here for more information |
||||
| VStructural LLC (VSL) / Williams |
1-3/4" Bar System | System Drawings | 2/14/12 | 3.16MB |
| Unbonded External Construction with Unbonded Anchors (Rehabilitation or Add-on Tendons) |
| None Currently Approved |