EMERGENCY INFORMATION FDOT Emergency Travel Alert: For information on the current situation, please visit the following page - Alerts.

Office of Design

Download the free Adobe Acrobat Reader to view and/or print Indexes. Entire Index Groups may be printed by selecting the group's Index Title at the default 11 X 17 inch size. Any available Instructions for Design Standards (IDS) are listed with their related Index. For Index related questions, please select the contact listed beside Index Title group headings. For use concerning plans incorporation, effective dates and for information on the Data Tables select the General Web Site Information link.

 

To skip directly to groups of Indexes, click on the index series:

100, 200, 300, 400, 500, 600, 700, 800, 5200, 6000, 11200, 13000, 17300, 17500, 17700, 17900, 18100, 20000, 20500, 20600, 20900, 21100, 21200, 21300, 21600, 21800, 21900

Design Standards eBooklet Index Title Revision Design Information
Index No Total Sheets Instructions for Design Stds (IDS) Data Table Cell Library Borderless DGNs

(PDF)

(PDF) (ZIP) (ZIP)
Terms of Use
 
Complete eBooklet
(257mb)

934

Year 2013 Design Standards eBooklet   Combined Available IDS
(10mb)
Combined Available CELs
(1mb)
Combined Available DGNs
(55mb)
  COVER, TABLE OF CONTENTS AND REVISIONS  
Cover 3 Booklet Cover   Cover    
Content 2 Table of Contents   Content    
Revisions 2 Revision History   Introduction    
Revisions
  ABBREVIATIONS AND SYMBOLS Roadway Contact
001 4 Standard Abbreviations        
002 3 Standard Symbols        
  EROSION CONTROL AND WATER QUALITY Hydraulics Contact
104 2 Permanent Erosion Control        
105 1 Shoulder Sodding and Turf on Existing Facilities        
 

DRAINAGE

(199-288, 293-295) Hydraulics Contact
(289-292) Structures Contact
199 1 Geotextile Criteria        
200 5 Structure Bottoms - Type J & P        
201 5 Supplementary Details for Manholes & Inlets        
205 6 Cover Height        
206 2 Trench Drain        
210 1 Curb Inlet Tops - Types 1, 2, 3 & 4        
211 5 Curb Inlet Tops - Types 5 & 6        
212 1 Curb Inlet - Type 7        
213 1 Curb Inlet - Type 8        
214 1 Curb Inlet Top - Type 9        
215 1 Curb Inlet Top - Type 10        
216 3 Closed Flume Inlet        
217 2 Median Barrier Inlets Types 1, 2, 3, 4 and 5        
218 2 Barrier Wall Inlet        
219 3 Concrete Barrier Wall Inlet        
220 3 Gutter Inlet - Type S        
221 2 Gutter Inlet - Type V        
230 2 Ditch Bottom Inlet - Type A        
231 3 Ditch Bottom Inlet - Type B        
232 7 Ditch Bottom Inlets - Types C, D, E and H        
233 2 Ditch Bottom Inlets - Types F and G        
234 2 Ditch Bottom Inlet - Type J        
235 2 Ditch Bottom Inlet - Type K        
240 2 Skimmer for Outlet Control Structures        
241 1 Skimmers for Frenchdrain Outlets        
245 1 Underdrain Inspection Box        
250 2 Straight Concrete Endwalls - Single and Multiple Pipe        
251 2 Straight Concrete Endwalls - Single and Double 60" Pipe        
252 2 Straight Concrete Endwalls - Single and Double 66" Pipe        
253 2 Straight Concrete Endwalls - Single and Double 72" Pipe        
255 1 Straight Concrete Endwall - Single 84" Pipe        
258 1 Straight Sand - Cement Endwalls        
260 1 U-Type Concrete Endwalls With Grates - 15" to 30" Pipe        
261 3 U-Type Concrete Endwalls - Baffles and Grate Optional - 15" to 30" Pipe        
264 2 U-Type Concrete Endwall - Energy Dissipator - 30" to 72" Pipe        
266 1 Winged Concrete Endwalls - Single Round Pipe        
268 1 U-Type Sand-Cement Endwalls        
270 1 Flared End Section        
272 6 Cross Drain Mitered End Section        
273 7 Side Drain Mitered End Section        
280 3 Miscellaneous Drainage Details        
281 2 Ditch Pavement and Sodding        
282 3 Back of Sidewalk Drainage        
283 1 Median Opening Flume        
284 1 Concrete Shoulder Gutter Spillway        
285 2 French Drain        
286 2 Underdrain        
287 4 Concrete Pavement Subdrainage        
288 1 Deep Well Injection Box        
289 8 Concrete Box Culvert Details (LRFD)   IDS-289 CEL-289 DGN-289
291 5 Supplemental Details for Precast Concrete Box Culverts   IDS-291   DGN-291
292 14 Standard Precast Concrete Box Culverts   IDS-292   DGN-292
293 1 Safety Modifications for Inlets In Box Culverts        
295 1 Safety Modifications for Endwalls        
  CURBS, CONCRETE PAVEMENT & SIDEWALKS Roadway Contact
300 2 Curb & Curb And Gutter        
301 1 Turn Lanes        
302 4 Traffic Separators   IDS-302    
303 1 Curb Return Profiles        
304 6 Public Sidewalk Curb Ramps        
305 4 Concrete Pavement Joints        
306 1 Bridge Approach Expansion Joint - Concrete Pavement        
307 3 Miscellaneous Utility Details        
308 2 Concrete Slab Replacement        
310 2 Concrete Sidewalk        
 

TRAFFIC RAILINGS

(400-417, 430 & 461) Roadway Contact
(420-425, 470-484) Structures Contact
400 26 Guardrail        
402 24 Guardrail Transitions and Connections for Existing Bridges   IDS-402    
403 3 Guardrail Transitions for Existing Bridge Traffic Railing Retrofits   IDS-403    
410 25 Concrete Barrier Wall        
411 10 Pier Protection Barrier   IDS-411    
412 5 Low Profile Barrier        
414 15 Type K Temporary Concrete Barrier System   IDS-414    
415 7 Temporary Concrete Barrier        
420 4 Traffic Railing - (32" F Shape)   IDS-420   DGN-420
421 4 Traffic Railing - (Median 32" F Shape)   IDS-421   DGN-421
422 3 Traffic Railing - (42" Vertical Shape)   IDS-422   DGN-422
423 3 Traffic Railing - (32" Vertical Shape)   IDS-423   DGN-423
424 7 Traffic Railing - (Corral Shape)   IDS-424   DGN-424
425 3 Traffic Railing - (42" F Shape)   IDS-425   DGN-425
430 2 Crash Cushion Details R2013-05 IDS-430    
461 1 Opaque Visual Barrier        
470 3 Traffic Railing - (Thrie Beam Retrofit) General Notes & Details   IDS-470   DGN-470
471 4 Traffic Railing - (Thrie Beam Retrofit) Narrow Curb     DGN-471
472 4 Traffic Railing - (Thrie Beam Retrofit) Wide Strong Curb Type 1     DGN-472
473 4 Traffic Railing - (Thrie Beam Retrofit) Wide Strong Curb Type 2     DGN-473
474 4 Traffic Railing - (Thrie Beam Retrofit) Intermediate Curb     DGN-474
475 4 Traffic Railing - (Thrie Beam Retrofit) Wide Curb Type 1     DGN-475
476 4 Traffic Railing - (Thrie Beam Retrofit) Wide Curb Type 2     DGN-476
480 2 Traffic Railing - (Vertical Face Retrofit) General Notes & Details   IDS-480   DGN-480
481 3 Traffic Railing - (Vertical Face Retrofit) Narrow Curb     DGN-481
482 4 Traffic Railing - (Vertical Face Retrofit) Wide Curb     DGN-482
483 3 Traffic Railing - (Vertical Face Retrofit) Intermediate Curb     DGN-483
484 10 Traffic Railing - (Vertical Face Retrofit) Spread Footing Approach     DGN-484
 

GENERAL

(500,505-535,544-591) Roadway Contact
(501,540) Structures Contact
500 2 Removal of Organic and Plastic Material        
501 12 Geosynthetic Reinforced Soils   IDS-501   DGN-501
505 4 Embankment Utilization        
506 1 Miscellaneous Earthwork Details        
510 2 Superelevation - Rural Highways, Urban Freeways and High Speed Urban Highways        
511 3 Superelevation - Urban Highways and Streets        
514 2 Optional Base Group and Structural Numbers        
515 7 Turnouts        
516 1 Turnouts - Resurfacing Projects        
518 3 Rumble Strips        
521 1 Concrete Steps   IDS-521    
525 5 Ramp Terminals        
526 8 Roadway Transitions        
527 3 Directional Median Openings        
530 3 Rest Area Pavilion        
532 3 Mailboxes        
535 1 Tractor Crossings        
540 1 Settlement Plate       DGN-540
544 3 Landscape Installation        
546 6 Sight Distance at Intersections        
560 2 Railroad Crossings        
591 1 Landscape Irrigation Sleeves        
  TRAFFIC CONTROL THROUGH WORK ZONES Roadway Contact
600 13 General Information for Traffic Control Through Work Zones        
601 1 Two-Lane, Two-Way, Work Outside Shoulder        
602 1 Two-Lane, Two-Way, Work on Shoulder        
603 2 Two-Lane, Two-Way, Work Within the Travel Way        
604 1 Two-Lane, Two-Way, Work in intersection        
605 1 Two-Lane, Two-Way, Work Near Intersection        
606 4 Two-Lane, Two-Way, Work Within the Travel Way - Signal Control        
607 1 Two-Lane, Two-Way, Mobile Operation, Work on Shoulder, Work Within the Travel Way        
608 1 Two-Lane, Two-Way, Temporary Diversion Connection        
611 1 Multilane, Work Outside Shoulder        
612 1 Multilane, Work on Shoulder        
613 2 Multilane, Work Within the Travel Way - Median or Outside Lane        
614 2 Multilane, Work Within the Travel Way - Center Lane        
615 1 Multilane, Work in Intersection        
616 3 Multilane, Work Near Intersection - Median or Outside Lane        
617 1 Multilane, Work in Intersection - Center Lane        
618 1 Multilane, Work in Intersection - Two Lanes Closed - 45 mph or Less        
619 2 Multilane, Mobile Operations, Work on Shoulder, Work Within the Travel Way        
620 2 Multilane, Divided, Temporary Diversion Connection        
621 1 Multilane, Undivided, Temporary Diversion Connection        
622 1 Multilane, Work Near Intersection-Temporary Diversion Connection-35 mph or Less        
623 1 Multilane, Work Within the Travel Way Double Lane Closure        
625 1 Temporary Road Closure - 5 Minutes or Less        
628 1 Two-Way Left Turn Lane Closure        
630 2 Crossover for Paving Train Operations, Rural        
631 2 Temporary Crossover        
635 1 Work in Vicinity of Railroad Crossing        
640 2 Converting Two-Lanes to Four-Lanes Divided, Rural        
641 3 Converting Two-Lanes to Four-Lanes Divided, Urban        
642 1 Transitions for Temporary Concrete Barrier Wall on Freeway Facilities        
650 2 Two-Lane, Two-Way Rural Structure Replacement        
651 2 Multilane, Divided, Maintenance and Construction        
655 3 Traffic Pacing        
660 1 Pedestrian Control for Closure of Sidewalks        
665 1 Limited Access, Temporary Opening        
667 6 Toll Plaza, Traffic Control Standards        
670 1 Motorist Awareness System        
 

ROADSIDE SAFETY

Roadway Contact
700 2 Roadside Offsets        
 

FENCING AND PEDESTRIAN RAILINGS

(800-803, 870-880) Roadway Contact
(810-862) Structures Contact
800 2 Fence Location        
801 3 Fence - Type A        
802 3 Fence - Type B        
803 1 Cantilever Slide Gate - Type B Fence        
810 4 Bridge Fencing (Vertical)   IDS-810   DGN-810
811 3 Bridge Fencing (Curved Top)   IDS-811   DGN-811
812 4 Bridge Fencing (Enclosed)   IDS-812   DGN-812
820 1 Bridge Pedestrian/Bicycle Bullet Railing   IDS-820   DGN-820
821 1 Bridge Aluminum Pedestrian/Bicycle Bullet Railing for Traffic Railing (32" F Shape)   IDS-821   DGN-821
822 3 Bridge Aluminum Pedestrian/Bicycle Bullet Railing Details   IDS-822   DGN-822
825 1 42" Concrete Pedestrian/Bicycle Railing   IDS-825   DGN-825
851 3 Bridge Pedestrian/Bicycle Railing (Steel)   IDS-851   DGN-851
852 8 Steel Pedestrian/Bicycle Railing   IDS-852 CEL-852

CEL-852-CTIP

DGN-852
861 3 Bridge Pedestrian/Bicycle Railing (Aluminum)   IDS-861   DGN-861
862 8 Aluminum Pedestrian/Bicycle Railing   IDS-862 CEL-862

CEL-862-CTIP

DGN-862
870 5 Aluminum Pipe Guiderail   IDS-870    
880 5 Steel Pipe Guiderail   IDS-880    
 

SOUND BARRIER SYSTEMS

Structures Contact
5200 16 Precast Sound Barriers   IDS-5200 CEL-5200

CEL-5200-Graphics

DGN-5200
5210 5 Traffic Railing/Sound Barrier (8'-0")   IDS-5210   DGN-5210
5211 3 Traffic Railing/Sound Barrier (14'-0")   IDS-5211   DGN-5211
5212 2 Traffic Railing/Sound Barrier (8'-0") Junction Slab   IDS-5212   DGN-5212
5213 2 Traffic Railing/Sound Barrier T-Shape Spread Footing   IDS-5213   DGN-5213
5214 4 Traffic Railing/Sound Barrier L-Shaped Spread Footing   IDS-5214   DGN-5214
5215 1 Traffic Railing/Sound Barrier Trench Footing   IDS-5215   DGN-5215
 

WALL SYSTEMS

Structures Contact
6010 2 C-I-P Cantilever Retaining Wall   IDS-6010 CEL-6010 DGN-6010
6011 1 C-I-P Gravity Wall   IDS-6011   DGN-6011
6020 1 Permanent MSE Retaining Wall Systems   IDS-6020 CEL-6020 DGN-6020
6030 1 Temporary MSE Retaining Wall Systems   IDS-6030 CEL-6030 DGN-6030
6040 4 Precast Concrete Sheet Pile Wall   IDS-6040 CEL-6040-CSPDA

CEL-6040-CSPC

CEL-6040-CSPSA

DGN-6040
6100 2 MSE Wall Coping (Precast or C-I-P)   IDS-6100   DGN-6100
6110 6 Wall Coping With Traffic Railing/Junction Slab     DGN-6110
6120 3 Wall Coping With Traffic Railing/Raised Sidewalk     DGN-6120
6130 2 Wall Coping/Parapet With C-I-P Sidewalk     DGN-6130
6200 3 Coping Mounted Light Pole Pedestal       DGN-6200
6201 1 Junction Slab at Drainage Inlet Openings       DGN-6201
 

SIGNING AND MARKING

(All Others) Roadway Contact
(11870) Structures Contact
11200 2 Multi-Column Ground Sign   IDS-11200    
11300 1 Steel Overhead Sign Structures        
11310 5 Cantilever Sign Structure   IDS-11310 CEL-11310  
11320 5 Span Sign Structure   IDS-11320 CEL-11320  
11860 8 Single Column Ground Signs   IDS-11860    
11870 2 Single Post Bridge Mounted Sign Support   IDS-11870   DGN-11870
11871 2 Single Post Median Barrier Mounted Sign Support R2013-01 IDS-11871    
13417 1 Mounting Exit Number Panels to Highway Signs        
17302 1 Typical Sections for Placement of Single & Multi-Column Signs        
17328 2 Typical Signing for Truck Weigh and Inspection Stations        
17344 6 School Signs & Markings        
17345 4 Interchange Markings R2013-02      
17346 14 Special Marking Areas R2013-02      
17347 4 Bicycle Markings        
17349 1 Traffic Controls for Street Terminations        
17350 1 Signing for Motorist Services        
17351 2 Welcome Center Signing        
17352 2 Typical Placement of Reflective Pavement Markers        
17354 1 Tourist Oriented Directional Signs        
17355 11 Special Sign Details        
17356 1 Span Wire Mounted Sign Details        
17357 1 Bridge Weight Restrictions        
17359 2 Rural Narrow Bridge Treatment        
 

ROADWAY LIGHTING

Roadway Contact
17500 3 Conventional Lighting        
17501 1 Highway Lighting General Notes        
17502 6 Highmast Lighting   IDS-17502    
17504 1 Service Point Details        
17505 2 External Lighting for Signs        
17515 8 Standard Aluminum Lighting   IDS-17515    
 

TRAFFIC SIGNAL AND EQUIPMENT

Roadway Contact
17600 3 Motorist Aid Call Box        
17700 1 Pull, Splice and Junction Box        
17721 2 Conduit Installation Details        
17723 3 Steel Strain Pole   IDS-17723    
17725 8 Concrete Poles   IDS-17725    
17727 2 Signal Cable and Span Wire Installation Details R2013-03      
17733 1 Aerial Interconnect        
17736 1 Electric Power Service        
17743 2 Standard Mast Arm Assemblies   IDS-17743 CEL-17743  
17745 5 Mast Arm Assemblies   IDS-17745 CEL-17745  
17748 1 Free-Swinging, Internally-Illuminated Street Sign Assemblies        
17764 1 Pedestrian Control Signal Installation Details        
17781 2 Vehicle Loop Installation Details        
17784 2 Pedestrian Detector Assembly Installation Details        
17841 1 Cabinet Installation Details        
17870 2 Standard Signal Operating Plans        
17881 1 Advance Warning for R/R Crossing        
17882 4 Railroad Grade Crossing Traffic Control Devices        
17890 3 Traffic Control Devices for Movable Span Bridge Signals        
 

PLANNING

Roadway Contact
17900 7 Traffic Monitoring Site        
  INTELLIGENT TRANSPORTATION SYSTEMS Intelligent Transportation Systems Contact
18100 1 CCTV Pole Placement        
18101 1 Typical CCTV Site        
18102 2 CCTV Pole Grounding        
18104 1 Typical CCTV Cabinet Equipment Layout        
18105 1 CCTV Block Diagram        
18107 1 Ground Mounted CCTV Cabinet        
18108 1 Pole Mounted CCTV Cabinet        
18110 2 Camera Mounting Details        
18111 2 Steel CCTV Pole        
18113 2 Concrete CCTV Pole        
18202 1 Fiber Optic Trench Details        
18300 10 Dynamic Message Sign Walk-In        
 

PRESTRESSED CONCRETE BEAMS

Structures Contact
20005 1 Prestressed I-Beam Temporary Bracing   IDS-20005 CEL-20005 DGN-20005
20010 2 Typical Florida I-Beam Details and Notes   IDS-20010 CEL-20010 DGN-20010
20036 2 Florida-I 36 Beam - Standard Details   DGN-20036
20045 2 Florida-I 45 Beam - Standard Details   DGN-20045
20054 2 Florida-I 54 Beam - Standard Details   DGN-20054
20063 2 Florida-I 63 Beam - Standard Details   DGN-20063
20072 2 Florida-I 72 Beam - Standard Details   DGN-20072
20078 2 Florida-I 78 Beam - Standard Details   DGN-20078
20084 2 Florida-I 84 Beam - Standard Details   DGN-20084
20096 2 Florida-I 96 Beam - Standard Details   DGN-20096
20199 1 Build-Up & Deflection Data for Florida-I Beams   IDS-20199 CEL-20199 DGN-20199
20210 2 Typical Florida U Beam Details and Notes   IDS-20210 CEL-20210 DGN-20210
20248 3 Florida U 48 Beam - Standard Details   DGN-20248
20254 3 Florida U 54 Beam - Standard Details   DGN-20254
20263 3 Florida U 63 Beam - Standard Details   DGN-20263
20272 3 Florida U 72 Beam - Standard Details   DGN-20272
20299 1 Build-up and Deflection Data for Florida U Beams   IDS-20299 CEL-20299 DGN-20299
 

BRIDGE BEARINGS

Structures Contact
20502 1 Beveled Bearing Plate Details - Prestressed Florida U-Beams   IDS-20502 CEL-20502 DGN-20502
20510 1 Composite Elastomeric Bearing Pads - Prestressed Florida-I Beams   IDS-20510 CEL-20510 DGN-20510
20511 2 Bearing Plates (Type I) - Prestressed Florida-I Beams   IDS-20511 CEL-20511 DGN-20511
20512 2 Bearing Plates (Type 2) - Prestressed Florida-I Beams   IDS-20512 CEL-20512 DGN-20512
 

SQUARE AND ROUND CONCRETE PILES

Structures Contact
20600 1 Notes and Details for Square Prestressed Concrete Piles   IDS-20600 CEL-20600 DGN-20600
20601 1 Square Prestressed Concrete Pile Splices   DGN-20601
20602 1 EDC Instrumentation for Square Prestressed Concrete Piles   DGN-20602
20612 1 12'' Square Prestressed Concrete Pile   DGN-20612
20614 1 14'' Square Prestressed Concrete Pile   DGN-20614
20618 1 18'' Square Prestressed Concrete Pile   DGN-20618
20620 1 20'' Square Prestressed Concrete Pile   DGN-20620
20624 1 24'' Square Prestressed Concrete Pile   DGN-20624
20630 1 30'' Square Prestressed Concrete Pile   DGN-20630
20631 1 High Moment Capacity 30'' Square Prestressed Concrete Pile   DGN-20631
20654 2 54'' Precast/Post-Tensioned Concrete Cylinder Pile   IDS-20654 DGN-20654
20660 2 60'' Prestressed Concrete Cylinder Pile   IDS-20660 DGN-20660
 

APPROACH SLABS

Structures Contact
20900 2 Approach Slabs (Flexible Pavement Approaches)   IDS-20900 CEL-20900 DGN-20900
20910 2 Approach Slabs (Rigid Pavement Approaches)   IDS-20910 CEL-20910 DGN-20910
 

BRIDGE EXPANSION JOINTS

Structures Contact
21100 3 Strip Seal Expansion Joint   IDS-21100 CEL-21100 DGN-21100
21110 2 Poured Joint With Backer Rod Expansion Joint System   IDS-21110 CEL-21110 DGN-21110
 

STRUCTURES ACCESS AND LIGHTING

Structures Contact
21200 3 Light Pole Pedestal   IDS-21200   DGN-21200
21210 2 Conduit Details   IDS-21210   DGN-21210
21220 2 Navigation Light System Details (Fixed Bridges)   IDS-21220   DGN-21220
21240 2 Maintenance Lighting for Box Girders   IDS-21240   DGN-21240
21250 1 Access Hatch Assembly for Steel Box Sections   IDS-21250   DGN-21250
21251 1 Access Hatch Assembly for Concrete Box Sections     DGN-21251
 

STANDARD BAR BENDING DETAILS

Structures Contact
21300 1 Standard Bar Bending Details   IDS-21300   DGN-21300
 

TEMPORARY DETOUR BRIDGES

Structures Contact
21600 7 Temporary Detour Bridge General Notes and Details   IDS-21600   DGN-21600
21610 3 Temporary Detour Bridge Details -Timber Pile Foundations     DGN-21610
21620 2 Temporary Detour Bridge Details -Steel H Pile Foundations     DGN-21620
21630 3 Temporary Detour Bridge Details -Steel Pipe Pile Foundations     DGN-21630
 

POST-TENSION DETAILS

Structures Contact
21801 2 Post-Tensioning Vertical Profiles   IDS-21800 CEL-21800b


CEL-21800t

DGN-21801
21802 1 Post-Tensioning Anchorage Protection   DGN-21802
21803 3 Post-Tensioning Anchorage and Grouting Details   DGN-21803
 

FENDER SYSTEM DETAILS

Structures Contact
21900 7 Fender System- Polymeric Piles   IDS-21900 CEL-21900 DGN-21900
21930 7 Fender System -Prestressed Concrete Piles   IDS-21930 CEL-21930 DGN-21930