Skip Navigation – Go to Main Content
Florida Department Of Transportation
Rotating image which displays various FDOT modes of travel
Your browser is currently set to not allow scripting. This site is best viewed with scripting turned on.
Several essential aspects of this site will not function with scripting disabled.

November 7, 2011 -- The Florida Department of Transportation's websites will be unavailable due to data center consolidation and relocation activities, beginning Thursday, November 10, 2011, 6:00 PM (EST). Services should resume by Monday, November 14, 2011 6:00 AM. We apologize for any inconvenience.

 May is Motorcycle Safety Awareness Month. Click here to read the proclamation. 
Main Level Navigation



 

Office Level Navigation



        Contact Us
 
State Roadway Design Office  605 Suwannee St., MS-32 Tallahassee, FL  32399-0450 Office Phone: (850) 414-4310  Office FAX:(850) 414-5261
 
Information on this web page may, at times, be temporarily unavailable due to scheduled maintenance. If you receive an error message, please try again at a later point in time. If you continue to experience problems, please contact our Web Author.
FDOT Facilities
Maps - FDOT Facilities (Opens in a new window)
FDOT - Roadway Design - Criteria and Standards

Highway

Roadway Design Office
 
Design Standards
  2004 Interim Standards Files - English

 

Interim Standard Index Sheets are to be included in FDOT construction plans, maintenance contracts and permits which are used to update the Standard Index Booklet to which they are referenced. They are in Adobe format. The default print size is 11x17 on the Page Set-up option. Typical file sizes are between 72kb to 1756kb, with most being under 500k. Entire groups may be printed by selecting the group name when shown as a link. Bentley’s Microstation design file format is NOT available for distribution.  Other Indexes may be revised by Design Standards Modifications.

For questions, please email John Mauthner, PE.

 

Index No. Sheet No. Filename Description

Index
Date

0201

4 & 5 of 6

0201.pdf

Supplementary Details For Manholes And Inlets - Dated 07-01-05 - These sheets replace sheets 4 and 5 in the existing 2004 Booklet. 

07/01/05

0232

1 of 5

0232.pdf

Ditch Bottom Inlets Types C,D,E & H - Dated 07-01-05 - These sheets replaces sheets 1 in the existing 2004 Booklet. 

07/01/05

0304

1-6 of 6

0304.pdf

Public Sidewalk Curb Ramps - Date: 01-01-05 - These sheets replace sheets 1 thru 5 of the 2004 Booklet. 

01/01/05

0400

1 of 1

04001of1.pdf

Guardrail - End Anchorage Assembly type REGENT-C Date: 08-21-03 - This sheet is a supplement to Index No. 400. This end anchorage system can be used when specifically called for in the plans or at the contractor's option whenever the plans call for the flared end anchorage option. This Interim should be included in all plans to the extent practical without adverse impact to production schedules and budgets beginning immediately. 

08/21/03

403

1-2 of 2

403.pdf

Guardrail Transitions For Existing Bridge Traffic Railing Retrofits - Dated 07-01-05 - This is a new Index to detail upgrading the guardrail approaches to existing bridge rail retrofits.

07/01/05

412 1-5 of 5 412.pdf Portable Temporary Low Profile Barrier For Roadside Safety - Date: 09-29-03 - This barrier is applicable for design speeds of 45 mph or less where a low profile is desired to maintain sight distance at intersections and driveways. This Interim may be used beginning immediately. Please note that availability of the device will be limited initially, since the precast industry will need time for mobilizing and tooling up to begin fabrication. This should be considered in establishing project schedules when calling for this device.  09/29/03
430 1-2 of 2 430.pdf Optional Crash Cushion Details - Dated 07-01-05 - This is a new Index to provide details for allowing the use of an optional crash cushion pay item.. 07/01/05
0670 1 of 1 0670.pdf Motorist Awareness System - Date 07-01-05 Note: Replaces Index No. 670. Tables for buffer space and taper length and for device spacing added. For information on implementation prior to January 1, 2006 refer to the Construction Office webpage at: http://www.dot.state.fl.us/construction/
memos/2005/DCE06005.pdf
07/01/05
05000 1 of 1 05000.pdf Retaining Wall System General Notes - Date: 08-21-03  - Replaces Index No. 5000. Increased depth of ground cover on concrete leveling pad. Deleted payment note. 08/21/03
05015 1-16 of 16 05015.pdf Retaining Wall Systems, The Reinforced Earth Company, Reinforced Earth Wall – Date: 01-01-05 – This Interim Index replaces the existing Index 5015.  It incorporates an alternate soil reinforcement type called High Adherence (HA) Ladders and new light pilaster details. 01/01/05
05025 1-16 of 16 05025.pdf Retaining Wall Systems, Tensar Earth Technologies, MSE Retaining Wall – Date: 01-01-05 – This Interim Index replaces the existing Index 5025. It incorporates a new panel/soil reinforcement connection called the “Bodkin Splice”. 01/01/05
5035 1-14 of 14 5035.pdf Retaining Wall Systems, SSL, MSE Plus Wall Systems – Date: 01-01-05 – This is a permanent wall system that can be used in slightly or moderately aggressive environments. 01/01/05
5040 1-13 of 13 5040.pdf Retaining Wall Systems, Hilfiker Square Panel – Date: 07-01-05 – This  permanent wall system is distributed by Hilfiker Retaining Walls and replaces deleted Index No. 5021. This Interim Index is not listed in the Design Standards Modifications effective July 1, 2005, but may be utilized on projects in accordance with the implementation requirements of combined Temporary Design Bulletin C05-05/DCE Construction Memorandum No. 12-05. 07/01/05
5045 1-13 of 13 5045.pdf Retaining Wall Systems, T&B Square Panel – Date: 07-01-05 –  This  permanent wall system is distributed by T&B Structural Systems Inc., and replaces deleted Index No. 5021. This Interim Index is not listed in the Design Standards Modifications effective July 1, 2005, but may be utilized on projects in accordance with the implementation requirements of combined Temporary Design Bulletin C05-05/DCE Construction Memorandum No. 12-05. 07/01/05
05115 1-6 of 6 05115.pdf Retaining Wall Systems, The Reinforced Earth Company, Terratrel Wire Wall – Date: 01-01-05 – This Interim Index replaces the existing Index 5115.  It incorporates an alternate soil reinforcement type called High Adherence (HA) Ladders. 01/01/05
05125 1-5 of 5 05125.pdf Retaining Wall Systems, Tensar Earth Technologies, Temporary Retaining Wall – Date: 01-01-05 – This Interim Index replaces the existing Index 5125.  It incorporates a new wire basket/soil reinforcement connection called the “Sierrascape” connection. 01/01/05
5110 1-5 of 5 5110.pdf Retaining Wall Systems, T & B Structural Systems, Inc. – Date: 01-01-05 – This is a temporary wire face wall that can be used in all environments. 01/01/05
5140 1-5 of 5 5140.pdf Retaining Wall Systems, Hilfiker Temporary Wire Wall – Date: 07-01-05 –  This is a new temporary wall system distributed by Hilfiker Retaining Walls. This Interim Index is not listed in the Design Standards Modifications effective July 1, 2005, but may be utilized on projects in accordance with the implementation requirements of combined Temporary Design Bulletin C05-05/DCE Construction Memorandum No. 12-05. 07/01/05
017346 5 of 13 017346.pdf Special Marking Areas - Date: 01-01-05 - This sheet replaces sheet 5 of 13 of the existing sheet of the 2004 Booklet. 01/01/05
017500 1 of 3 017500.pdf Conventional Lighting - Date: 01-01-05 - This sheet replaces sheet 1 of 3 of the existing sheet of the 2004 Booklet. 01/01/05
017900 5 of 9 017900.pdf Traffic Monitoring - Date: 01-01-05 - This sheet replaces sheet 5 of 9 of the existing sheet of the 2004 Booklet. 01/01/05

 

     
 

This page was last modified on 01/05/2012

 

 

 

Accessibility | Acronyms | Frequently Asked Questions | Governor's Office | Privacy Policy | Statement of Agency  

Email questions and comments to: 
Public Information Office for General Issues
Web Review Team for Website Issues
Copyright © 1996- Florida Department of Transportation

You might need Word Viewer or Adobe Reader to view file downloads

My Florida logo image  (Opens in New Window)
spacer image