|
November 7, 2011
-- The Florida Department of Transportation's websites will be unavailable due to data center consolidation
and relocation activities, beginning Thursday, November 10, 2011, 6:00 PM (EST). Services should resume
by Monday, November 14, 2011 6:00 AM. We apologize for any inconvenience. |
|
|
|
FDOT - Roadway Design - Criteria and Standards
|

|
-

-
Design Standards
- 2000
|
Online access to Design Standards is provided for
the purpose of on screen observation and print reproduction effective on all
English and Metric jobs beginning with the July letting. They are in
Adobe format. Revisions made by Modifications or Interim Standards are
not included. These Standards may be purchased online in paper form by
placing an order online at our
Maps and Publications On-Line Store. The default print size is 8.5
x 11, however to print standard plan size sheets, select 11x17 on the Page
Set-up option. Typical file sizes are between 72kb to 9791kb, with most
being under 500k. Entire groups may be printed by selecting the group
name when shown as a link.
Bentley’s
Microstation design file format is NOT available for distribution. However,
those for Structures drawings (e.g. Bridge Components, overhead sign
structures, proprietary retaining wall systems etc) are available at the
Structures Design Office Website.
Note that approved proprietary items are
listed on the
Qualified Products List and the
Approved Product List and are NOT shown in these Design Standards.
Design Standards Procedure (Topic #
625-010-003-g.) is available.
For questions, please email
John Mauthner, PE.
|
*
COVER AND INTRODUCTION *
|
|
Index No.
|
Sheet No.
|
Filename
|
Description
|
| - |
1-2
of 2 |
Cover1-2of2.pdf |
2000
English Roadway And Traffic Design Standards booklet
Cover |
| - |
1
of 1 |
Intro2000.pdf |
2000
English Roadway And Traffic Design Standards booklet Introduction |
| - |
1-2
of 2 |
Contents2000.pdf |
2000
English Roadway And Traffic Design Standards booklet Table
Of Contents |
|
*
ABBREVIATIONS AND SYMBOLS *
|
| 001 |
1-2
of 2 |
00001s1-2of2.pdf |
Standard
Abbreviations |
| 002 |
1-3
of 3 |
00002s1-3of3.pdf |
Standard
Symbols |
|
* EROSION CONTROL AND
WATER QUALITY * |
| 100 |
1
of 1 |
00100s01.pdf |
Temporary
Slope Drain And Sod Flume |
| 101 |
1
of 1 |
00101s01.pdf |
Trash
Retainer And Sediment Basin |
| 102 |
1-3
of 3 |
00102s1-3of3.pdf |
Rock
Bag, Baled Hay And Silt Fence Barriers |
| 103 |
1
of 1 |
00103s01.pdf |
Turbidity
Barriers |
| 104 |
1-2
of 2 |
00104s1-2of2.pdf |
Erosion
Control |
| 105 |
1
of 1 |
00105s01.pdf |
Shoulder
Sodding And Reworking On Existing Facilities |
| 106 |
1
of 1 |
00106s01.pdf |
Soil
Tracking Prevention Device Type A |
| 199 |
1
of 1 |
00199s01.pdf |
Geotextile
Criteria |
|
*
DRAINAGE * |
| 199 |
1
of 1 |
00199s01.pdf |
Geotextile
Criteria |
| 200 |
1-2
of 2 |
00200s1-2of2.pdf |
Structure
Bottoms - Type J And P |
| 201 |
1-6
of 6 |
00201s1-6of6.pdf |
Supplementary
Details For Manholes And Inlets |
| 205 |
1-5
of 5 |
00205s1-5of5.pdf |
Cover
Height |
| 210 |
1
of 1 |
00210s01.pdf |
Curb
Inlet Tops - Types 1, 2, 3 And 4 |
| 211 |
1-2
of 2 |
00211s1-2of2.pdf |
Curb
Inlet Tops - Types 5 And 6 |
| 212 |
1
of 1 |
00212s01.pdf |
Curb
Inlet - Type 7 |
| 213 |
1
of 1 |
00213s01.pdf |
Curb
Inlet - Type 8 |
| 214 |
1
of 1 |
00214s01.pdf |
Curb
Inlet Top - Type 9 |
| 215 |
1
of 1 |
00215s01.pdf |
Curb
Inlet Top - Type 10 |
| 216 |
1-2
of 2 |
00216s1-2of2.pdf |
Closed
Flume Inlet |
| 217 |
1
of 1 |
00217s01.pdf |
Median
Barrier Inlets Types 1, 2, 3, 4 And 5 |
| 218 |
1-2
of 2 |
00218s1-2of2.pdf |
Barrier
Wall Inlet |
| 219 |
1-2
of 2 |
00219s1-2of2.pdf |
Barrier
Wall Inlet - Barrier Wall, Concrete ( Rigid ) (C &
G) |
| 220 |
1
of 1 |
00220s01.pdf |
Gutter
Inlet - Type S |
| 221 |
1
of 1 |
00221s01.pdf |
Gutter
Inlet - Type V |
| 230 |
1
of 1 |
00230s01.pdf |
Ditch
Bottom Inlet - Type A |
| 231 |
1-2
of 2 |
00231s1-2of2.pdf |
Ditch
Bottom Inlet - Type B |
| 232 |
1-5
of 5 |
00232s1-5of5.pdf |
Ditch
Bottom Inlets - Types C, D, E And H |
| 233 |
1
of 1 |
00233s01.pdf |
Ditch
Bottom Inlets - Types F And G |
| 234 |
1
of 1 |
00234s01.pdf |
Ditch
Bottom Inlet - Type J |
| 235 |
1
of 1 |
00235s01.pdf |
Ditch
Bottom Inlet - Type K |
| 240 |
1-2
of 2 |
00240s1-2of2.pdf |
Skimmer
For Outlet Control Structures |
| 245 |
1
of 1 |
00245s01.pdf |
Underdrain
Inspection Box |
| 250 |
1-2
of 2 |
00250s1-2of2.pdf |
Straight
Concrete Endwalls - Single And Multiple Pipe |
| 251 |
1-2
of 2 |
00251s1-2of2.pdf |
Straight
Concrete Endwalls - Single And Double 60" Pipe |
| 252 |
1-2
of 2 |
00252s1-2of2.pdf |
Straight
Concrete Endwalls - Single And Double 66" Pipe |
| 253 |
1-2
of 2 |
00253s1-2of2.pdf |
Straight
Concrete Endwalls - Single And Double 72" Pipe |
| 255 |
1
of 1 |
00255s01.pdf |
Straight
Concrete Endwall - Single 84" Pipe |
| 258 |
1
of 1 |
00258s01.pdf |
Straight
Sand - Cement Endwalls |
| 260 |
1
of 1 |
00260s01.pdf |
U-Type
Concrete Endwalls With Grates - 15" To 30"
Pipe |
| 261 |
1-3
of 3 |
00261s1-3of3.pdf |
U-Type
Concrete Endwalls - Baffles And Grate Optional -
15" To 30" Pipe |
| 264 |
1
of 1 |
00264s01.pdf |
U-Type
Concrete Endwall - Energy Dissipator - 30" To
72" Pipe |
| 266 |
1
of 1 |
00266s01.pdf |
Winged
Concrete Endwalls - Single Round Pipe |
| 268 |
1
of 1 |
00268s01.pdf |
U-Type
Sand-Cement Endwalls |
| 270 |
1
of 1 |
00270s01.pdf |
Flared
End Section |
| 272 |
1-6
of 6 |
00272s1-6of6.pdf |
Cross
Drain Mitered End Section |
| 273 |
1-6
of 6 |
00273s1-6of6.pdf |
Side
Drain Mitered End Section |
| 280 |
1-4
of 4 |
00280s1-4of4.pdf |
Miscellaneous
Drainage Details |
| 281 |
1-2
of 2 |
00281s1-2of2.pdf |
Ditch
Pavement And Sodding |
| 282 |
1
of 1 |
00282s01.pdf |
Back
Of Sidewalk Drainage |
| 283 |
1
of 1 |
00283s01.pdf |
Median
Opening Flume |
| 284 |
1
of 1 |
00284s01.pdf |
Concrete
Spillways |
| 285 |
1-2
of 2 |
00285s1-2of2.pdf |
French
Drain |
| 286 |
1-2
of 2 |
00286s1-2of2.pdf |
Underdrain |
| 287 |
1-3
of 3 |
00287s1-3of3.pdf |
Concrete
Pavement Subdrainage |
| 290 |
1-5
of 5 |
00290s1-5of5.pdf |
Concrete
Box Culvert |
| 293 |
1
of 1 |
00293s01.pdf |
Safety
Modifications For Inlets In Box Culverts |
| 295 |
1
of 1 |
00295s01.pdf |
Safety
Modifications For Endwalls |
|
*
CURBS, CONCRETE PAVEMENT AND SIDEWALKS
* |
| 300 |
1
of 1 |
00300s01.pdf |
Curb
& Curb And Gutter |
| 301 |
1
of 1 |
00301s01.pdf |
Turn
Lanes |
| 302 |
1
of 1 |
00302s01.pdf |
Traffic
Separators |
| 303 |
1
of 1 |
00303s01.pdf |
Curb
Return Profiles |
| 304 |
1-5
of 5 |
00304s1-5of5.pdf |
Public
Sidewalk Curb Ramps |
| 305 |
1-4
of 4 |
00305s1-4of4.pdf |
Concrete
Pavement Joints |
| 306 |
1
of 1 |
00306s01.pdf |
Bridge
Approach Expansion Joint - Concrete Pavement |
| 307 |
1
of 1 |
00307s01.pdf |
Utility
Cut |
| 310 |
1-2
of 2 |
00310s1-2of2.pdf |
Concrete
Sidewalk |
|
* TRAFFIC RAILINGS * |
| 400 |
1-10
of 31 |
00400s1-10of31.pdf |
Guardrail |
| 11-21
of 31 |
00400s11-21of31.pdf |
Guardrail |
| 22-31
of 31 |
00400s22-31of31.pdf |
Guardrail |
| 401 |
1-9
of 9 |
00401s1-9of9.pdf |
Guardrail
Anchorage And Continuous Barrier For Existing Bridges |
| 410 |
1-11
of 22 |
00410s1-11of22.pdf |
Concrete
Barrier Wall |
| 12-22
of 22 |
00410s12-2of22.pdf |
Concrete
Barrier Wall |
| 415 |
1-4
of 4 |
00415s1-4of4.pdf |
Precast
Concrete Temporary Barrier Wall |
| 416 |
1-5
of 5 |
00416s1-5of5.pdf |
Temporary
Water Filled Barriers |
| 417 |
1
of 1 |
00417s01.pdf |
Inertial
Crash Cushion |
| 432 |
1-2
of 2 |
00432s1-2of2.pdf |
C-A-T
350 |
| 433 |
1-4
of 4 |
00433s1-4of4.pdf |
Brakemaster
350 |
| 434 |
1
of 1 |
00434s01.pdf |
REACT
350 |
| 435 |
1-6
of 6 |
00435s1-6of6.pdf |
QuadGuard |
| 436 |
1
of 1 |
00436s01.pdf |
ADIEM
350 |
| 438 |
1-2
of 2 |
00438s1-2of2.pdf |
Dragnet |
| 440 |
1-2
of 2 |
00440s1-2of2.pdf |
TRACC |
| 450 |
1-2
of 2 |
00450s1-2of2.pdf |
Fence
Location |
| 451 |
1-2
of 2 |
00451s1-2of2.pdf |
Fence
- Type A |
| 452 |
1-2
of 2 |
00452s1-2of2.pdf |
Fence
- Type B |
| 453 |
1
of 1 |
00453s01.pdf |
Cantilever
Slide Gate - Type B Fence |
| 461 |
1
of 1 |
00461s01.pdf |
Opaque
Visual Barrier |
|
*
GENERAL * |
| 500 |
1-2
of 2 |
00500s1-2of2.pdf |
Removal
Of Organic And Plastic Material |
| 501 |
1-8
of 8 |
00501s1-8of8.pdf |
Geosynthetic
Reinforced Soils |
| 505 |
1-3
of 3 |
00505s1-3of3.pdf |
Embankment
Utilization |
| 506 |
1
of 1 |
00506s01.pdf |
Miscellaneous
Earthwork Details |
| 510 |
1-2
of 2 |
00510s1-2of2.pdf |
Superelevation
- Rural Highways, Urban Freeways And High Speed Urban
Highways |
| 511 |
1-3
of 3 |
00511s1-3of3.pdf |
Superelevation
- Urban Highways And Streets |
| 514 |
1-2
of 2 |
00514s1-2of2.pdf |
Optional
Base Group And Structural Numbers |
| 515 |
1-6
of 6 |
00515s1-6of6.pdf |
Turnouts |
| 516 |
1
of 1 |
00516s01.pdf |
Turnouts
- Resurfacing Projects |
| 518 |
1-2
of 2 |
00518s1-2of2.pdf |
Rumble
Strips |
| 520 |
1-2
of 2 |
00520s1-2of2.pdf |
Aluminum
Pipe Handrails, Gravity Walls And Steps |
| 525 |
1-5
of 5 |
00525s1-5of5.pdf |
Ramp
Terminals |
| 526 |
1-8
of 8 |
00526s1-8of8.pdf |
Roadway
Transitions |
| 530 |
1-3
of 3 |
00530s1-3of3.pdf |
Rest
Area Equipment |
| 532 |
1-3
of 3 |
00532s1-3of3.pdf |
Mailboxes |
| 535 |
1
of 1 |
00535s01.pdf |
Tractor
Crossings |
| 540 |
1
of 1 |
00540s01.pdf |
Settlement
Plate |
| 544 |
1
of 1 |
00544s01.pdf |
Landscape
Installation |
| 546 |
1-2
of 2 |
00546s1-2of2.pdf |
Sight
Distance At Intersections |
| 560 |
1-5
of 5 |
00560s1-5of5.pdf |
Railroad
Crossings |
|
*
TRAFFIC CONTROL THROUGH WORK ZONES * |
| 600 |
1-5
of 11 |
00600s1-5of11.pdf |
General
Information For Traffic Control Through Work Zones |
| 6-11
of 11 |
00600s6-11of11.pdf |
General
Information For Traffic Control Through Work Zones |
| 601 |
1
of 1 |
00601s01.pdf |
Two-Lane,
Two-Way Rural Day Or Night Operations |
| 602 |
1
of 1 |
00602s01.pdf |
Two-Lane,
Two-Way Rural Day Or Night Operations |
| 603 |
1-2
of 2 |
00603s1-2of2.pdf |
Two-Lane,
Two-Way Rural Operations One Daylight Period Or Less |
| 604 |
1
of 1 |
00604s01.pdf |
Two-Lane,
Two-Way Rural Night Operations Or Operations Exceeding
One Daylight Period |
| 605 |
1
of 1 |
00605s01.pdf |
Two-Lane,
Two-Way Rural Moving Operations - Daylight Only |
| 606 |
1
of 1 |
00606s01.pdf |
Two-Lane,
Two-Way Rural Moving Operations - Daylight Only |
| 607 |
1
of 1 |
00607s01.pdf |
Two-Lane,
Two-Way Rural Short-Time Day Or Night Operations |
| 608 |
1-4
of 4 |
00608s1-4of4.pdf |
Two-Lane,
Two-Way Lane Closure By Signal Control, Day Or Night
Operations |
| 609 |
1
of 1 |
00609s01.pdf |
Two-Lane,
Two-Way Rural Temporary Connection Day Or Night
Operations |
| 610 |
1
of 1 |
00610s01.pdf |
Multilane,
Divided Or Undivided Rural Day Or Night Operations |
| 611 |
1
of 1 |
00611s01.pdf |
Multilane,
Divided Or Undivided Rural Day Or Night Operations |
| 612 |
1
of 1 |
00612s01.pdf |
Multilane,
Divided And Undivided Rural, Operations One Daylight
Period Or Less |
| 613 |
1-2
of 2 |
00613s1-2of2.pdf |
Multilane,
Divided And Undivided Rural Night Operations Or
Operations Exceeding One Daylight Period |
| 614 |
1-2
of 2 |
00614s1-2of2.pdf |
Multilane
Divided Rural Day Or Night Operations |
| 615 |
1
of 1 |
00615s01.pdf |
Multilane
Undivided Rural Day Or Night Operations |
| 616 |
1-2
of 2 |
00616s1-2of2.pdf |
Multilane
Divided Rural |
| 617 |
1
of 1 |
00617s01.pdf |
Multilane
Divided Rural |
| 620 |
1
of 1 |
00620s01.pdf |
Two-Lane,
Two-Way Urban Day Or Night Operations |
| 621 |
1
of 1 |
00621s01.pdf |
Two-Lane,
Two-Way Urban Day Or Night Operations |
| 622 |
1
of 1 |
00622s01.pdf |
Multilane,
Two-Way Urban Divided Or Undivided Day Or Night
Operations |
| 623 |
1-2
of 2 |
00623s1-2of2.pdf |
Multilane,
Two-Way Urban Divided Or Undivided Day Or Night
Operations |
| 624 |
1
of 1 |
00624s01.pdf |
Multilane,
Divided With Traversable Median Or Undivided, Urban Day
Or Night Operations |
| 625 |
1-2
of 2 |
00625s1-2of2.pdf |
Multilane
One-Way Or Multilane Divided With Non-Traversable Median
Urban Day Or Night Operations |
| 626 |
1
of 1 |
00626s01.pdf |
Multilane
One-Way Or Multilane Divided With Non-Traversable Median
Urban Day Or Night Operations |
| 627 |
1
of 1 |
00627s01.pdf |
Moving
Operations |
| 628 |
1
of 1 |
00628s01.pdf |
Two-Way
Left Turn Lane Closure |
| 630 |
1-2
of 2 |
00630s1-2of2.pdf |
Temporary
Crossover For Paving Train Operations, Rural |
| 631 |
1-2
of 2 |
00631s1-2of2.pdf |
Temporary
Crossover |
| 640 |
1-2
of 2 |
00640s1-2of2.pdf |
Converting
Two-Lanes To Four-Lanes Divided Rural |
| 641 |
1-2
of 2 |
00641s1-2of2.pdf |
Converting
Two-Lanes To Four-Lanes Divided Urban |
| 650 |
1-2
of 2 |
00650s1-2of2.pdf |
Two-Lane,
Two-Way Rural Structure Replacement |
| 651 |
1-2
of 2 |
00651s1-2of2.pdf |
Multilane
Divided Maintenance And Construction |
| 660 |
1
of 1 |
00660s01.pdf |
Pedestrian
Control For Closure Of Sidewalks |
| 665 |
1
of 1 |
00665s01.pdf |
Limited
Access Right Of Way Temporary Opening |
| |
|
|
|
|
*
WALL AND SOUND BARRIER SYSTEM * |
| 5000 |
1
of 1 |
05000s01.pdf |
Permanent
And Temporary Walls - General Wall Notes |
| 5005 |
1-6
of 12 |
05005s1-6of12.pdf |
Permanent
Walls - Retained Earth Systems |
| 7-12
of 12 |
05005s7-12of12.pdf |
Permanent
Walls - Retained Earth Systems |
| 5010 |
1-10
of 20 |
05010s1-10of20.pdf |
Permanent
Walls - T-Wall ( 3" Cover ) |
| 11-20
of 20 |
05010s11-20of20.pdf |
Permanent
Walls - T-Wall ( 3" Cover ) |
| 5011 |
1-11
of 21 |
05011s1-11of21.pdf |
Permanent
Walls - T-Wall ( 2" Cover ) |
| 12-21
of 21 |
05011s12-21of21.pdf |
Permanent
Walls - T-Wall ( 2" Cover ) |
| 5012 |
1-10
of 20 |
05012s1-10of20.pdf |
Permanent
Walls - Isogrid |
| 11-20
of 20 |
05012s11-20of20.pdf |
Permanent
Walls - Isogrid |
| 5015 |
1-7
of 14 |
05015s1-7of14.pdf |
Permanent
Walls - Reinforced Earth Wall |
| 8-14
of 14 |
05015s8-14of14.pdf |
Permanent
Walls - Reinforced Earth Wall |
| 5016 |
1-8
of 8 |
05016s1-8of8.pdf |
Permanent
Walls - Techwall |
| 5020 |
- |
- |
Reserved |
| 5021 |
1-7
of 13 |
05021s1-7of13.pdf |
Permanent
Walls - Hilfiker Square Panel Wall |
| 8-13
of 13 |
05021s8-13of13.pdf |
Permanent
Walls - Hilfiker Square Panel Wall |
| 5025 |
1-9
of 17 |
05025s1-9of17.pdf |
Permanent
Walls - MSE Retaining Wall |
| 10-17
of 17 |
05025s10-17of17.pdf |
Permanent
Walls - MSE Retaining Wall |
| 5105 |
1-3
of 3 |
05105s1-3of3.pdf |
Permanent
Walls - Wire Face Wall |
| 5115 |
1-4
of 4 |
05115s1-4of4.pdf |
Permanent
Walls - Terratrel Wire Wall |
| 5120 |
1-4
of 4 |
05120s1-4of4.pdf |
Permanent
Walls - Hilfiker Welded Wire Wall |
| 5125 |
1-3
of 3 |
05125s1-3of3.pdf |
Permanent
Walls - Tensar Temporary Wall |
| 5130 |
1-4
of 4 |
05130s1-4of4.pdf |
Permanent
Walls - TC Mirafi Wire Form |
|
*
SIGNING AND MARKINGS * |
| 9535 |
1-3
of 3 |
09535s1-3of3.pdf |
Standard
Roadside Sign Break-Away Post Details |
|
*
SIGNS * |
| 11037 |
1
of 1 |
11037s01.pdf |
Aluminum
& Steel Overhead Sign Structures ( Details Of Sign
Faces & Truss Connection ) |
| 11860 |
1-3
of 3 |
11860s1-3of3.pdf |
Single
Column Ground Signs ( Sign Profile & Identification
Numbers ) |
| 11861 |
1-2
of 2 |
11861s1-2of2.pdf |
Single
Column Ground Signs ( 60 mph ) |
| 11862 |
1-2
of 2 |
11862s1-2of2.pdf |
Single
Column Ground Signs ( 70 mph ) |
| 11863 |
1-2
of 2 |
11863s1-2of2.pdf |
Single
Column Ground Signs ( 80 mph ) |
| 11864 |
1-2
of 2 |
11864s1-2of2.pdf |
Single
Column Ground Signs ( 90 mph ) |
| 11865 |
1-2
of 2 |
11865s1-2of2.pdf |
Single
Column Ground Signs ( All Wind Zones ) |
|
*
EXIT NUMBERING SIGNS * |
| 13417 |
1
of 1 |
13417s01.pdf |
Mounting
Exit Numbering Panels To Highway Signs |
|
*
SIGNING AND MARKINGS * |
| 17302 |
1
of 1 |
17302s01.pdf |
Typical
Sections For Placement Of Single & Multi-Column
Signs |
| 17328 |
1
of 1 |
17328s01.pdf |
Typical
Signing For Truck Weigh & Inspection Stations |
| 17344 |
1-6
of 6 |
17344s1-6of6.pdf |
School
Signs & Markings |
| 17345 |
1-4
of 4 |
17345s1-4of4.pdf |
Interchange
Markings |
| 17346 |
1-9
of 9 |
17346s1-9of9.pdf |
Special
Marking Areas |
| 17349 |
1
of 1 |
17349s01.pdf |
Traffic
Controls For Street Terminations |
| 17350 |
1
of 1 |
17350s01.pdf |
Signing
For Motorist Services |
| 17351 |
1-2
of 2 |
17351s1-2of2.pdf |
Welcome
Center Signing |
| 17352. |
1-2
of 2 |
17352s1-2of2.pdf |
Typical
Placement Of Reflective Pavement Markers |
| 17355 |
1-12
of 12 |
17355s1-12of12.pdf |
Special
Sign Details |
| 17356 |
1-2
of 2 |
17356s1-2of2.pdf |
Span
Wire Mounted Sign Details |
| 17357 |
1
of 1 |
17357s01.pdf |
Bridge
Weight Restrictions |
| 17359 |
1
of 1 |
17359s01.pdf |
Rural
Narrow Bridge Treatment |
|
*
ROADWAY LIGHTING * |
| 17500 |
1-3
of 3 |
17500s1-3of3.pdf |
Conventional
Lighting |
| 17501 |
1
of 1 |
17501s01.pdf |
Highway
Lighting General Notes |
| 17502 |
1-4
of 4 |
17502s1-4of4.pdf |
Highmast
Lighting Details |
| 17503 |
1
of 1 |
17503s01.pdf |
Roadway
Lighting Details |
| 17504 |
1
of 1 |
17504s01.pdf |
Service
Point Details |
| 17505 |
1-2
of 2 |
17505s1-2of2.pdf |
External
Lighting For Signs ( Mercury Vapor ) |
|
*
TRAFFIC SIGNAL AND EQUIPMENT * |
| 17600 |
1-2
of 2 |
17600s1-2of2.pdf |
Motorist
Aid Call Box |
| 17721 |
1-2
of 2 |
17721s1-2of2.pdf |
Conduit
Installation Details |
| 17725 |
1
of 1 |
17725s01.pdf |
Concrete
Poles |
| 17727 |
1-2
of 2 |
17727s1-2of2.pdf |
Signal
Cable And Span Wire Installation Details |
| 17733 |
1
of 1 |
17733s01.pdf |
Aerial
Interconnect |
| 17736 |
1
of 1 |
17736s01.pdf |
Electric
Power Service |
| 17764 |
1
of 1 |
17764s01.pdf |
Pedestrian
Control Signal Installation Details |
| 17781 |
1-2
of 2 |
17781s1-2of2.pdf |
Vehicle
Loop Installation Details |
| 17784 |
1-2
of 2 |
17784s1-2of2.pdf |
Pedestrian
Detector Assembly Installation Details |
| 17841 |
1
of 1 |
17841s01.pdf |
Cabinet
Installation Details |
| 17870 |
1-2
of 2 |
17870s1-2of2.pdf |
Standard
Signal Operating Plans |
| 17881 |
1
of 1 |
17881s01.pdf |
Advance
Warning For R/R Crossing |
| 17882 |
1-4
of 4 |
17882s1-4of4.pdf |
Railroad
Grade Crossing Traffic Control Devices |
| 17890 |
1-3
of 3 |
17890s1-3of3.pdf |
Traffic
Control Devices For Movable Span Bridge Signals |
|
*
MISCELLANEOUS * |
| 17900 |
1-9
of 9 |
17900s1-9of9.pdf |
Traffic
Monitoring Site |
|
|
|
|
|
|
|
|
This page was last
modified on
01/05/2012 |
|
|
|